Powerline 2 Starters - Direct On Line Starters to 18.5kW |
|
Features
|
|
|
IP55 Direct On Line
| Starter Type |
Max FLC |
Max. Rating 3 Phase kW / HP AC3 |
Order Code |
||||||||
220V |
380/440V |
240/250V Coil Supply* |
Encl. Size |
415/440V Coil Supply* |
Encl. Size |
415/110V Control Cct Tx |
Encl. Size |
||||
HP |
kW |
HP |
kW |
||||||||
| DOL without isolator | 8.5 | 3.0 | 2.2 | 5.5 | 4.0 | PAD0000BN | 1 | PAD | 1 | PAD00001T | 3 |
| 16 | 5.5 | 4.0 | 10.0 | 7.5 | PCD0000BN | 1 | PCD | 1 | PCD00001T | 3 | |
| 22 | 7.5 | 5.5 | 15.0 | 11.0 | PED0000BN | 1 | PED | 1 | PED00001T | 3 | |
| 37 | 15.0 | 11.0 | 25.0 | 18.5 | PGD0000BN | 2 | PGD | 2 |
|
||
| DOL with isolator |
8.5 | 3.0 | 2.2 | 5.5 | 4.0 | PAD00L0BN | 2 | PAD00L | 2 | PAD00L01T | 3 |
| 16 | 5.5 | 4.0 | 10.0 | 7.5 | PCD00L0BN | 2 | PCD00L | 2 | PCD00L01T | 3 | |
| 22 | 7.5 | 5.5 | 15.0 | 11.0 | PED00L0BN | 2 | PED00L | 2 | PED00L01T | 3 | |
| 37 | 15.0 | 11.0 | 25.0 | 18.5 | PGD00L0BN | 3 | PGD00L | 3 |
|
||
IP65 Direct On Line
| Starter Type |
Max FLC |
Max. Rating 3 Phase kW / HP AC3 |
Order Code |
||||||||
220V |
380/440V |
240/250V Coil Supply* |
Encl. Size |
415/440V Coil Supply* |
Encl. Size |
415/110V Control Cct Tx |
Encl. Size |
||||
HP |
kW |
HP |
kW |
||||||||
| DOL with isolator | 8.5 | 3.0 | 2.2 | 5.5 | 4.0 | PADP0L0BN | 2 | PADP0L | 2 | PADP0L01T | 3 |
| 16 | 5.5 | 4.0 | 10.0 | 7.5 | PCDP0L0BN | 2 | PCDP0L | 2 | PCDP0L01T | 3 | |
| 22 | 7.5 | 5.5 | 15.0 | 11.0 | PEDP0L0BN | 2 | PEDP0L | 2 | PEDP0L01T | 3 | |
| 37 | 15.0 | 11.0 | 25.0 | 18.5 | PGDP0L0BN | 3 | PGDP0L | 3 |
|
||
* Other coil voltages available on request
Single Phase Ratings
| Starter Type |
Max FLC | Maximum Ratings kW / HP |
|||||||
100/125V |
200/250V |
380/440V |
500/550V |
||||||
HP |
kW |
HP |
kW |
HP |
kW |
HP |
kW |
||
| PAD | 11 | 0.75 | 0.5 | 1.5 | 1.0 | 3.0 | 2.2 | 4.0 | 3.0 |
| PCD | 18 | 1.25 | 1.0 | 2.5 | 1.75 | 5.0 | 3.75 | 6.0 | 4.4 |
| PED | 24 | 1.75 | 1.3 | 3.5 | 2.6 | 7.0 | 5.25 | 8.75 | 6.5 |
Auxiliary Contacts
| All PAD, PCD & PED Starters | 1 spare normally closed auxiliary contact is fitted as standard 2 additional contact blocks can be fitted |
| All PGD Starters | No spare auxiliary contacts are fitted as standard 2 contact blocks can be fitted |
For full details of all Accessories Click Here
Overload
The starter is supplied without overload relay. This should be selected from the Westmaster Overload range and ordered separately.



Wiring Diagram - Direct On Line Type PAD, PCD & PED

Wiring Diagram - Direct On Line Type PGD

Typical Transformer Control Circuit
| Installation & Servicing Instructions | |||
| Motor Starters Catalogue | |||