Powerline 2 Starters - Direct On Line Reversing Starters to 18.5kW |
|
Features
|
|
|
IP55 Direct On Line Reversing
| Starter Type |
Max FLC |
Max. Rating 3 Phase kW / HP AC3 |
Order Code |
||||||||
220V |
380/440V |
240/250V Coil Supply* |
Encl. Size |
415/440V Coil Supply* |
Encl. Size |
415/110V Control Cct Tx |
Encl. Size |
||||
HP |
kW |
HP |
kW |
||||||||
| DOLR without isolator | 8.5 | 3.0 | 2.2 | 5.5 | 4.0 | PAX000#BN | 2 | PAD000# | 2 | PAX000#1T | 3 |
| 16 | 5.5 | 4.0 | 10.0 | 7.5 | PCX000#BN | 2 | PCD000# | 2 | PCX000#1T | 3 | |
| 22 | 7.5 | 5.5 | 15.0 | 11.0 | PEX000#BN | 2 | PED000# | 2 | PEX000#1T | 3 | |
| 37 | 15.0 | 11.0 | 25.0 | 18.5 | PGX000#BN | 3 | PGD000# | 3 |
|
||
| DOLR with isolator |
8.5 | 3.0 | 2.2 | 5.5 | 4.0 | PAX00L#BN | 3 | PAD00L# | 3 | PAX00L#1T | 3 |
| 16 | 5.5 | 4.0 | 10.0 | 7.5 | PCX00L#BN | 3 | PCD00L# | 3 | PCX00L#1T | 3 | |
| 22 | 7.5 | 5.5 | 15.0 | 11.0 | PEX00L#BN | 3 | PED00L# | 3 | PEX00L#1T | 3 | |
IP65 Direct On Line Reversing
| Starter Type |
Max FLC |
Max. Rating 3 Phase kW / HP AC3 |
Order Code |
||||||||
220V |
380/440V |
240/250V Coil Supply* |
Encl. Size |
415/440V Coil Supply* |
Encl. Size |
415/110V Control Cct Tx |
Encl. Size |
||||
HP |
kW |
HP |
kW |
||||||||
| DOLR without isolator | 8.5 | 3.0 | 2.2 | 5.5 | 4.0 | PAXP00#BN | 2 | PAXP00# | 2 | PAXP00#1T | 3 |
| 16 | 5.5 | 4.0 | 10.0 | 7.5 | PCXP00#BN | 2 | PCXP00# | 2 | PCXP00#1T | 3 | |
| 22 | 7.5 | 5.5 | 15.0 | 11.0 | PEXP00#BN | 2 | PEXP00# | 2 | PEXP00#1T | 3 | |
| 37 | 15.0 | 11.0 | 25.0 | 18.5 | PGXP00#BN | 3 | PGXP00# | 3 |
|
||
| DOLR with isolator |
8.5 | 3.0 | 2.2 | 5.5 | 4.0 | PAXP0L#BN | 3 | PAXP0L# | 3 | PAXP0L#1T | 3 |
| 16 | 5.5 | 4.0 | 10.0 | 7.5 | PCXP0L#BN | 3 | PCXP0L# | 3 | PCXP0L#1T | 3 | |
| 22 | 7.5 | 5.5 | 15.0 | 11.0 | PEXP0L#BN | 3 | PEXP0L# | 3 | PEXP0L#1T | 3 | |
| Replace # with either A or O | A = Pushbutton up & down, maintained or non-maintained operation. |
| O = Pushbutton forward & reverse, maintained only. |
Auxiliary Contacts
| PAX, PCX & PEX Starters, Maintained (O) Operation | No spare auxiliary contacts are fitted as standard. 1 additional contact block can be fitted to each contactor. |
| PAX, PCX & PEX Starters, Maintained / Non Maintained (A) Operation | 1 spare normally closed auxiliary contact is fitted to each contactor as standard. No additional contact blocks can be fitted. |
| PGX Starters, Maintained (O) Operation | 1 spare normally open auxiliary contact is fitted to each contactor as standard. No additional contact blocks can be fitted. |
| PGX Starters, Maintained / Non Maintained (A) Operation |
No spare auxiliary contacts are fitted as standard. No additional contact blocks can be fitted. |
For full details of all Accessories Click Here
Overload
The starter is supplied without overload relay. This should be selected from the Westmaster Overload range and ordered separately.



Wiring Diagram - Direct On Line Reversing, Maintained Operation Type PAX, PCC & PEX

Wiring Diagram - Direct On Line Reversing, Maintained & Non Maintained Operation Type PAX, PCC & PEX

Wiring Diagram - Direct On Line Reversing, Maintained Operation Type PGX

Wiring Diagram - Direct On Line Reversing, Maintained & Non Maintained Operation Type PGX
| Installation & Servicing Instructions | |||
| Motor Starters Catalogue | |||